内页Banner
Blog
What if the head and flow rate of the magnetic pump are too low? Mar 10, 2023

What is the cause of the low flow rate of fluoroplastic magnetic pump?

(1) the transportation resistance in the discharge pipe is too large.

(2) leakage of suction pipe.

(3) the speed is too low.

(4) the rotation direction is wrong.

(5) the cross-sectional area of the suction pipe is reduced.

(6) Magnetic drive is interrupted.

(7) the rotation direction of the motor is wrong.

How to deal with the low flow rate of fluoroplastic magnetic pump?

(1) check the cleaning pipe and replace the pipeline and valve.

(2) check the tightening torque of the apricot suction pipe joint and bolts; check the gasket of the suction inlet; check the tightening torque of the bolts on the pump shell; check the gasket on the pump and replace the new gasket.

(3) check the frequency and voltage of the motor.

(4) reconnect the power cord or adjust the phase of the motor according to the direction of rotation of the pump.

(5) clean the suction inlet filter, remove the sediment in the suction pipe or replace the suction pipe.

(6) turn off the motor. After waiting for the machine to stop, restart the motor.

(7) change the rotation direction of the motor.

What is the reason why the head of fluoroplastic magnetic pump is too low?

(1) the resistance of the discharge pipe is too low.

(2) the outlet pressure is too low and the reference suction height is too high.

(3) leakage of suction pipe.

(4) the speed is too low.

(5) the viscosity and density of the liquid are too high.

(6) the rotation direction is wrong.

Fluoroplastic magnetic pump lift is not too low how to deal with?

(1) adjust the control valve on the discharge line.

(2) increase the outlet pressure.

(3) check the flange of the pipeline. And bolt tightening force; check the sealing gasket of the suction inlet, check the sealing gasket on the pump shell, check the tightening force of the bolts on the pump shell, and replace the new hot plate.

(4) check motor frequency and voltage.

(5) reconnect the power cord or adjust the phase of the motor according to the direction of rotation arrow.

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

Skype

WhatsApp